{
  "schema": "mtplus-update/1",
  "generated": "2026-11-10",
  "app": {
    "version": "1.3.1",
    "url": "https://vrftools.com/mtplus/MTplus-Setup-1.3.1.exe",
    "sha256": "ed17ae010b00c48b8e892a4651e3c803db410228d28fd7d7509880e00fcfbaca",
    "size_bytes": 15166336,
    "built": "2026-11-10",
    "channel": "stable",
    "notes": [
      "A quick tour on first launch. The first time MT+ opens on a PC it points out the main window, the read buttons, Open Output Folder, Port Verification and the Help menu.",
      "A Port Verification walkthrough. Until you are Certified, your first Port Verification on the demo site opens a click-through walkthrough of the screen and of a verification, then drops you into the real demo run. Help \u25b8 Port Verification Walkthrough opens it again at any time.",
      "Read-only or the demo, with a converter connected. Until you are Certified, each launch with a converter asks whether to continue read-only on the live equipment or start the demo.",
      "The demo starts itself on a first launch with no converter. After that, launching with no converter shows a large Start demo site button in the middle of the window, and the newsletter prompt stays out of the way.",
      "On the demo site, Port Verification is ringed in red once the address search finishes, and Stop is ringed once the search is past address 100, where the demo has nothing left to find.",
      "The connection tree shows each indoor unit's size, as in IC 6 (72 MBH).",
      "Exiting Port Verification leaves the log at the top of its report.",
      "A 16-port BC no longer runs off the edge of the Port Verification window: it scrolls sideways (Shift+wheel too), the window fits a short screen, and a width you drag it to stays.",
      "Releasing a held port shows the position it had before you held it straight away.",
      "A unit that takes two ports shows both in its Port column, as in 6/7."
    ]
  },
  "bundle": {
    "mt_version": "5.60.0.7",
    "min_engine_version": "1.0",
    "generated": "2026-06-25"
  },
  "history": [
    {
      "version": "1.0.0",
      "url": "https://vrftools.com/mtplus/MTplus-Setup-1.0.0.exe",
      "sha256": "e93a0a7b59707c37331d3a258ef0d9de3b393d89237baecbaa0080c0a5a27fd3",
      "size_bytes": 13759400,
      "built": "2026-09-26",
      "channel": "stable",
      "notes": [
        "The address search reads every unit in full as it finds it and prints each one the moment it is read. A unit reading Power Outage is pink; one Maintenance Tool would show red is red and bold. After the grid, each system is drawn as a map: outdoor units, BCs, and every port with the indoor units on it.",
        "While a tool runs, the log stays on its newest line, and its progress shows in the status bar at the bottom.",
        "New: a Feedback button on the bottom row. After Port Verification or Evac closes, its border pulses red for a few seconds. It sends only what you type, which tool, your tier and the version, and waits on the laptop if there's no internet.",
        "Port Verification opens with every indoor unit's port already filled in from the address search, loads each unit's temperatures and then its mode, and shows the BC's valve rows filling and draining while they're read. When you close it, the log shows a table of each unit's assigned port, actual port and result, with every other row shaded. Any SW14 changes it needs are in one boxed card, steps in order, ready to photograph.",
        "Evac Mode's system picker draws each system's map. The status area shows whether each outdoor unit is communicating, the power-off step names them (\"Turn off power to OC 51 and OS 52\"), and the power-loss step waits until every one of them has stopped talking.",
        "Help \u25b8 About says who made MT+.",
        "MT+ has its own icon on every window.",
        "The session file is now session.MTPlus, capitalised like MT's own .MTDZ. The session folder holds only files you open: the raw log and Port Verification's working log stay hidden while MT+ runs and go inside the session file when it closes.",
        "No more Address Search or Connected Capacity CSV (the session file still has it all), the Dip Switch CSVs no longer end in raw bytes, and Models and Serials drops its TypeCode column.",
        "MT-SPY is now MT+. It installs next to MT-SPY as a new program with its own settings; uninstall MT-SPY whenever you're ready.",
        "New: Help \u25b8 Register\u2026 redeems an activation code. Type your email and the code, press Redeem, and the extra tools light up with no restart.",
        "The main screen groups its buttons in three rows by what they do to the equipment: Read, Write and Command. A tool your code unlocked has a coloured outline for its tier, and a tool your code doesn't reach isn't shown.",
        "At startup the strip under the log asks you to join the VRFTools newsletter. Once your subscription is confirmed, it doesn't come back.",
        "MT+ asks for an optional site name under the log and names the session folder with it. The converter connects while you type, and the address search starts when you press Enter.",
        "What changed in a new version is listed in the log the first time it runs.",
        "The tools use the address search's system map, so they stay right after you power a system down.",
        "Port Verification comes up the moment you pick a system and fills in as the scan line walks the units, instead of sitting blank. The scan walks each BC's SVA, SVB and SVC rows while its valves are read, and a held port's Actual port column gets an orange box. Test Run and All Stop fill their button like a progress bar while their commands go out.",
        "Evac Mode lists one button per outdoor unit, with its BCs and indoor units beside it, and puts each unit on the system it reported at the address search. A system you have already powered down no longer shows its BC as a system of its own, and its indoor units no longer show up on the next one. On X-Gen, a grid shows every BC port's LEV positions. A drive button fills like a progress bar while its commands go out, and after the outdoor unit loses power every unit is read once more, so the whole list agrees.",
        "A session folder holds just the CSVs and one session file, and every tool now writes a CSV.",
        "Port Verification is built around the indoor unit: isolate a port, then click the numbered box on the row of the unit that reacted.",
        "Port Verification marks the row it is reading, and shows the BC solenoids again.",
        "Function Settings is one button. It reads the outdoor units, then asks whether to read the indoor units too.",
        "A question a tool asks now appears just above the buttons, not at the top of the window.",
        "Set ODU Date/Time shows clock drift in days, hours and minutes.",
        "Every tool has a help page, and Help \u25b8 Open in Browser\u2026 opens the whole book.",
        "If a session file can't be saved, the raw log is kept instead of deleted.",
        "Evacuation Mode is now a step-by-step walkthrough, and needs the DSG tier while it is field tested."
      ]
    },
    {
      "version": "1.0.1",
      "url": "https://vrftools.com/mtplus/MTplus-Setup-1.0.1.exe",
      "sha256": "43ee87bc8920cf2b2add70bbaf6f5cee781988a76630aade6bd5bb222e4a2aaa",
      "size_bytes": 14866399,
      "built": "2026-09-27",
      "channel": "stable",
      "notes": [
        "Help opens in your browser, and that is the only help now: Help \u25b8 Contents, or F1. It has a search box, and every tool's page shows you the screen, with the button to press boxed in red. The longer tools have a walkthrough that plays step by step; pause it, or step back and forth with the arrows.",
        "Start MT+ with no converter plugged in and it says so, in the log and the status bar, instead of sitting on \"Starting\u2026\". Plug the converter in and it connects on its own.",
        "Set ODU Date/Time says which clock is ahead: \"PC is 3d 2h ahead\".",
        "Evac Mode's unit table starts at the top of its window.",
        "The installer has a new look and a licence agreement to accept. It ticks Create a desktop shortcut for you, and it only starts MT+ at the end if you tick Launch MT+."
      ]
    },
    {
      "version": "1.1.0",
      "url": "https://vrftools.com/mtplus/MTplus-Setup-1.1.0.exe",
      "sha256": "b9c95d814dccad69fed4c92c6e3e53b67dd4514ebf29970130b954083b466f65",
      "size_bytes": 15002461,
      "built": "2026-09-29",
      "channel": "stable",
      "notes": [
        "New for DSG: the demo site, a simulated job site for trying every tool or showing MT+ to someone. Start MT+ with no converter plugged in and the strip under the log offers Start demo site where the site name would go. Help has a page on it, The demo site.",
        "On the demo, everything runs at twice a real wire's speed except Port Verification, which runs at real speed.",
        "File \u25b8 Demo Site Equipment\u2026 has a power switch for every unit on the demo, and Clear errors.",
        "A demo never passes for a real site: the status bar says SIMULATION, the session folder ends in DEMO, and every CSV starts with a SIMULATED SITE line. Restart MT+ with the converter plugged in to get back to real equipment.",
        "Port Verification shows each indoor unit's size in a Model column, filled in from the address search, and the address column is now M-Net. A size 72 or 96 unit takes two ports: click both and they turn green, and the result reads them as one, like 7+8.",
        "Switching back to a system in Port Verification no longer re-reads every port dial, and it shows each unit's On/Off and Mode as you left them until they are read again.",
        "Port Verification's first look at a system starts straight at the temperatures. The address search now reads what each indoor unit needs, where Port Verification used to read it unit by unit with the M-Net column lit.",
        "In Port Verification, the Test Run buttons count units as they send, not commands, and after a Test Run or All Stop every unit is read again the way the system first opens: its temperatures, then its On/Off and Mode, then the valves.",
        "Port Verification shows TH3 in red over 100 \u00b0F, where it was 120 \u00b0F.",
        "The orange box around a held port's column stays on that column while the temperatures fill in.",
        "Under the address grid, red units are listed with their error code: Error: IC05 (2502).",
        "The system map brackets a size 72 or 96 unit across both of its ports.",
        "Dip Switch Download marks every BC and BS, and any unit with no switch grid, with \"More testing needs to be done to be confident of these readings.\""
      ]
    },
    {
      "version": "1.2.0",
      "url": "https://vrftools.com/mtplus/MTplus-Setup-1.2.0.exe",
      "sha256": "b1f1603f5905d24bf93937aa6e7e839bbcd0f1c46a0bdbe7ab0f1622b4e5ed14",
      "size_bytes": 15011442,
      "built": "2026-09-30",
      "channel": "stable",
      "notes": [
        "New for DSG: Help \u25b8 Issue codes\u2026 makes codes for the people you train. A class code gives Certified to up to 20 people and lasts a week; it shows big enough for a projector, with a count of how many have used it. A one-time code gives Certified or Advanced to one technician, can be tied to their email, and lasts a day.",
        "New for DSG: a remote-unlock code. Remoted into a technician's laptop, make one and type it into Help \u25b8 Register\u2026 there, under For this run only. Your tools work on that laptop until MT+ closes. The code lasts 15 minutes and works once, and nobody types an email.",
        "My codes, in the same window, lists every code you made and the email of everyone who redeemed it. Switch off stops a code for anyone new.",
        "The Register dialog now says that whoever gave you a code can see the email you redeem it with.",
        "An expired code now says it has expired, and to email support@vrftools.com for a new one."
      ]
    },
    {
      "version": "1.2.1",
      "url": "https://vrftools.com/mtplus/MTplus-Setup-1.2.1.exe",
      "sha256": "49a65da3a743af5f39761459824b8574fcef10bf8766d70ab8329b64c70b57f7",
      "size_bytes": 15010309,
      "built": "2026-10-07",
      "channel": "stable",
      "notes": [
        "Evac Mode is now open to the Certified tier. It has been field-tested on legacy systems only: on an X-Gen system the window says not yet field tested the whole time it is open.",
        "The demo site is now open to the Certified tier.",
        "Help \u25b8 Register\u2026 has one place to type: your email and the activation code. The field for pasting a key is gone.",
        "In Port Verification, a port's orange ring shows the moment you click it, then stays or goes once the port has been driven and read.",
        "After Port Verification or Evac Mode closes, the Feedback button's red ring is thicker and brighter, and beats for about 25 seconds."
      ]
    },
    {
      "version": "1.3.0",
      "url": "https://vrftools.com/mtplus/MTplus-Setup-1.3.0.exe",
      "sha256": "c995ed3401125fee02200be49528137bb9534a1d634c705690fbd3baacb3585b",
      "size_bytes": 15151114,
      "built": "2026-11-01",
      "channel": "stable",
      "notes": [
        "Getting Certified has changed. Start the demo site and do a Port Verification on it; that run is your test. When you press Exit, vrftools.com checks it. Pass, and you type your email and press Register to get Certified. Fail, and it tells you which units were wrong and why. To try again, close MT+ and open it with no converter connected.",
        "The demo site is offered while Maintenance Tool is running. Start MT+ after MT and it leaves MT's converter alone, says so, and offers Start demo site, so you can try it while you take logs. MT opening after MT+ has connected is still companion mode, as before.",
        "The address search keeps its summary in view. The unit count, errors and power outages stay at the top while the system maps print below them, instead of the log running to the bottom and leaving you to scroll back up.",
        "Certified is earned on the demo site only. No code unlocks it any more, so Help \u25b8 Issue codes\u2026 makes no class codes and no Certified codes; a DSG's one-time code is Advanced. An Advanced technician no longer has Issue codes\u2026.",
        "Help \u25b8 Register\u2026 no longer has a test button. It tells you how to reach the demo site from wherever you are.",
        "Port Verification has an Exit button. If a Test Run is still on, it asks first, then stops the units the Test Run started and releases every valve. The Stop button and closing MT+ now stop those units too.",
        "Settings\u2026 on the Port Verification bar holds the Scan IDU Mode and Scan BC Solenoids counters, which used to sit on the bar.",
        "On a unit over 54 MBH that takes two ports, a click on its dialled port shuts both, and a click on the second port works that port alone. Its Actual Port record marks both boxes, and a click on either clears both.",
        "Clicking a valve no longer moves the scan line.",
        "The Port Verification report only covers systems where you overrode a port.",
        "On X-Gen systems, Port Verification no longer says the port valves are not yet verified.",
        "The address search starts as soon as the converter connects, and the site name is asked for after it.",
        "New: Compressor Hours lists every outdoor unit's compressor run hours and start counts, with the average run per start. It only reads.",
        "New for DSG, in Port Verification: Set Selected starts or stops chosen indoor units and can hold one unit's LEV; panels show the outdoor units' and BCs' readings; and a port hint marks the Actual Port box a held port most likely feeds.",
        "Help \u25b8 Issue codes\u2026 has Copy for every code, including a remote-unlock code.",
        "In Task Manager, MT+ now shows as MT+, not Python."
      ]
    }
  ],
  "prereleases": []
}
